CCX2000 cyclic chamber
$0.00
SKU
- DESCRIPTION
- DATA SHEET
- ACCESSORIES
- Capacity: 565lt/20cu.ft
Dimensions of the exhibition area: 1.27mx 0.74mx 0.63m
External dimensions: 2.4mx 0.9mx 1.4m
-
Used to qualify a coating or material for a wide range of end users, to rapidly qualify a coating or material on a pass/fail basis, or to predict the service life or determine the probability of corrosion of a specific material
Meets SAE J2334, ASTM G85 A4,Nissan CCT III/V, VW1210, Ford BI 123-01, GM9540P, Automotive CCT, Immersion, Variable Humidity; as well as exactly complying with the performance of the BCX chamber tests and the traditional Salt Fog and Humidity Tests
The chambers on the market are of 5 standard sizes: 2 ft3 to 110 ft3, 565 lt to 3115 lt
Translucent cover that allows you to view test conditions without having to open the cover
Angled cover prevents dripping into samples
227 lt Solution Container, the largest container for an advanced cyclic corrosion chamber
Wide temperature range; temperature control in the exposure zone from ambient to 71ºc / 160ºF: as an option, the high temperature kit can be used, which extends the range from -30ºC / -22ºF to 90ºc / 195ºF
Automatic Operation Cycles: Pre-installed standard test cycles such as: Salt Mist (electrolytes), Mist, Water Mist, Dry, Purge, Stop and cycles for any combination and time period
Touch Screen Operation: Easy-to-use controls with pre-installed test programs
Optional Computer Controls: including immersion, controlled humidity, freezing/cooling, very high, very low temperature, spray system
Certification according to CE, UL, CSA
Omni-Fog™ or Omni-Fog™ II Dispersion System, fully adjustable Frame support shelves, front and rear
Reinforced bottom supports
CONDITIONS FOR A BASIC CCX CYCLE CHAMBER
◦Salt Fog (electrolyte) and RH Saturation
◦Water Fog with RH Saturation
◦Drying
◦Detention
◦Humidity without condensation
◦Direct salt spray
◦High temperature, up to 71ºC / 160ºF
◦So2 injection
CONDITIONS FOR AN ADVANCED CYCLE CHAMBER
◦Saline and Water Mist, with automatic change
◦Controllable humidity, from room to RH saturation
◦Automatic Immersion
◦Second electrolyte by mist or direct spray
◦Ambient temperature and automatic RD
◦Very Low Temperature of -30ºC / -22ºF
◦Very High Temperature, 90ºC / 194ºC
Includes:
◦Cycle Control Package
◦RS232 serial interface port
◦Off Timer
◦Rotating screws for leveling
◦Easy in-line filter replacement for saline solutions and DI water.
◦Pressure gauge for bubble tower.
◦Low water level shutdown protection for bubble tower
◦Cover with air pistons for BCX9000 and BCX11000
◦Programmable logic control with operator interface panel
◦Universal electrical configuration that meets the frequency, voltage and local electrical requirements.
-
Download Here